Garden · GA-061

Roll-back compost rain-sheet support

Keep a removable rain sheet above a small leaf-compost pile while leaving the sides open and the sheet removable for turning.

Editorial construction draft. Original digital diagrams; no physical build or load certification. Read dimensions, fit and use limits before making changes. US customary dimensions control; metric values are references.

Before marking and cutting

Use limits

Materials and cuts

PartQtySize to cutMaterial
P01 End uprights230 × 1 1/2 × 1 1/2 in
762 × 38.1 × 38.1 mm
2 × 2 in board sound untreated wood
P02 Top roll beam136 × 1 1/2 × 1 1/2 in
914.4 × 38.1 × 38.1 mm
2 × 2 in board sound untreated wood
P03 Broad feet224 × 3 1/2 × 3/4 in
609.6 × 88.9 × 19.05 mm
1 × 4 in board sound untreated cedar or other durable untreated wood
P04 Sheet end batten136 × 1 1/2 × 3/4 in
914.4 × 38.1 × 19.05 mm
1 × 2 in board sound untreated cedar or other durable untreated wood; no unknown salvage

Hardware and consumables

Tools

Assembly

GA-061 dimensioned assembly
  1. Plan the roll-back compost rain-sheet support for this result: Keep a removable rain sheet above a small leaf-compost pile while leaving the sides open and the sheet removable for turning. Confirm the design reference before cutting: Top beam firmly fixed vertically; feet flat and restrained. In the drawings x runs left to right, y runs front to rear and z runs upward.
  2. Verify the required stock before laying out these parts: 1 × 2 in board: actual 0.75 × 1.5 in (19.05 × 38.1 mm); 1 × 4 in board: actual 0.75 × 3.5 in (19.05 × 88.9 mm); 2 × 2 in board: actual 1.5 × 1.5 in (38.1 × 38.1 mm). Reject split or twisted wood and unknown salvage; thinner stock requires recalculating the joints, not simply using the listed lengths.
  3. Cut and label the finished parts: 2 End uprights 30 × 1.5 × 1.5 in (762 × 38.1 × 38.1 mm), mark P01; 1 Top roll beam 36 × 1.5 × 1.5 in (914.4 × 38.1 × 38.1 mm), mark P02; 2 Broad feet 24 × 3.5 × 0.75 in (609.6 × 88.9 × 19.05 mm), mark P03; 1 Sheet end batten 36 × 1.5 × 0.75 in (914.4 × 38.1 × 19.05 mm), mark P04. Keep saw kerf outside each finished line. Rip only where the finished width is narrower than the actual stock; use a suitable guide and target ±1/16 in (1.6 mm) for ordinary cuts. Dowel triples mean length × diameter × diameter, not square dowel stock.
  4. Set the two uprights at 36 in outside width. Center a 24 in broad foot beneath each and predrill two underside fixing holes per post.
  5. Attach feet with 3 in screws, keeping them square to the upright line. Their long axes run front to rear for a broad unfilled footprint.
GA-061 dimensioned parts or elevation
  1. Lay the 36 in beam across post tops and attach vertically with two 3 in screws per post. No screw enters the side of a post with no overlap.
  2. Round all beam sheet-contact edges. Drape the waterproof sheet over the beam so water can run toward a separately suitable landscape area, never toward a building.
  3. Clip the 36 in end batten to the low sheet edge without piercing it. The batten is a loose roll-up weight, not a tensioned structural rail.
  4. Place the assembly over a small existing leaf pile without sealing its sides. Restrain both feet independently and leave access for air and turning.
  5. Test a small amount of water on the sheet and remove any sag that forms a water pocket. Stop if runoff erodes soil or reaches a watercourse.
  6. Roll the sheet onto the beam before turning the pile and remove the whole assembly before wind. No snow, ponded water or storm loading is permitted; this cover does not sanitize compost.
  7. Complete the acceptance checks below before putting the assembly into service. Record any changed stock thickness, fastener or equipment fit on the project sheet. The published geometry has not been physically built or load-tested.

Checks

Operation

Cleaning and maintenance

Primary context

These sources inform the context and do not endorse the original construction design.