Poultry · PO-008

Lift-out doorway litter kickboard

Retain loose bedding behind a removable doorway board while leaving the human door and emergency exit operable.

Editorial construction draft. Original digital diagrams; no physical build or load certification. Read dimensions, fit and use limits before making changes. US customary dimensions control; metric values are references.

Before marking and cutting

Use limits

Materials and cuts

PartQtySize to cutMaterial
A Kickboard136 × 8 × 3/4 in
914.4 × 203.2 × 19.05 mm
Exterior-bond plywood, measured actual thickness. Square ends; remove splinters.
B Guide backing210 × 2 1/2 × 3/4 in
254 × 63.5 × 19.05 mm
Untreated sound straight softwood. Square ends; remove splinters.
C Outer spacer210 × 1 × 3/4 in
254 × 25.4 × 19.05 mm
Untreated sound straight softwood. Square ends; remove splinters.
D Keeper strip210 × 2 1/2 × 3/4 in
254 × 63.5 × 19.05 mm
Untreated sound straight softwood. Square ends; remove splinters.

Hardware and consumables

Tools

Assembly

PO-008 dimensioned assembly
  1. Confirm the doorway has a clear mounting zone 37 3/4 in (958.9 mm) wide, and that a removable 8 in (203.2 mm) board will not interfere with an exit or become an unmarked trip hazard.
  2. Cut A to 36 × 8 in from actual 3/4 in plywood. Round its top corners and sand the upper edge smooth for lifting.
  3. Cut two each of B and D to 10 × 2 1/2 × 3/4 in. Cut C to 10 × 1 × 3/4 in by ripping actual stock to 1 in depth; the 1 in dimension creates the running gap.
  4. Mount B vertically with outside faces spanning 37 3/4 in; use anchors selected for sound existing jamb framing, not loose trim.
  5. Position C on each far outside edge. Attach each with two 1 1/4 in screws into B, at 2 and 8 in (50.8 and 203.2 mm) from the bottom.
  6. Dry-fit A centered between C; inner spacer faces are 36 1/4 in (920.8 mm) apart, giving 1/8 in (3.2 mm) side clearance per edge.
  7. Clamp D onto C. Drive three 2 in screws per D on C's centerline, maintaining the 1 in cavity around the 3/4 in board.
PO-008 dimensioned parts or elevation
  1. Slide A down onto a smooth existing threshold. It must come out vertically without removing D and without requiring fingers behind a sharp edge.
  2. Add a high-contrast removable label to the board's human side identifying the temporary step-over obstacle; keep labels and adhesives inaccessible to pecking.
  3. Open and close the main door fully. Carry the lifted board through the real exit route to verify rapid removal.
  4. Introduce bedding only after the board and retainers are secure. Do not pack litter so tightly that it prevents removal or holds the board wet.
  5. Remove before moving bulky supplies or when the doorway is used as a primary exit; clean and dry the track channels when litter begins to jam them.

Checks

Cleaning and maintenance

Primary context