Garden · GA-027

Eight-emitter comparison rail

Hold eight identical collection cups under drip emitters for a timed volume comparison without claiming a laboratory flow measurement.

Editorial construction draft. Original digital diagrams; no physical build or load certification. Read dimensions, fit and use limits before making changes. US customary dimensions control; metric values are references.

Before marking and cutting

Use limits

Materials and cuts

PartQtySize to cutMaterial
P01 Base136 × 7 1/4 × 3/4 in
914.4 × 184.15 × 19.05 mm
1 × 8 in board sound untreated cedar or other durable untreated wood; actual 3/4 × 7-1/4 in section
P02 Rear emitter rail136 × 1 1/2 × 3/4 in
914.4 × 38.1 × 19.05 mm
1 × 2 in board sound untreated cedar or other durable untreated wood; no unknown salvage
P03 Riser blocks23 1/4 × 1 1/2 × 1 1/2 in
82.55 × 38.1 × 38.1 mm
2 × 2 in board sound untreated wood
P04 Front cup stop136 × 1 1/2 × 3/4 in
914.4 × 38.1 × 19.05 mm
1 × 2 in board sound untreated cedar or other durable untreated wood; no unknown salvage

Hardware and consumables

Tools

Assembly

GA-027 dimensioned assembly
  1. Plan the eight-emitter comparison rail for this result: Hold eight identical collection cups under drip emitters for a timed volume comparison without claiming a laboratory flow measurement. Confirm the design reference before cutting: Base 36 × 7-1/4 in (914.4 × 184.15 mm); eight centers at 4-1/2 in pitch, y = 3-1/2 in. In the drawings x runs left to right, y runs front to rear and z runs upward.
  2. Verify the required stock before laying out these parts: 1 × 8 in board: actual 0.75 × 7.25 in (19.05 × 184.15 mm); 1 × 2 in board: actual 0.75 × 1.5 in (19.05 × 38.1 mm); 2 × 2 in board: actual 1.5 × 1.5 in (38.1 × 38.1 mm). Reject split or twisted wood and unknown salvage; thinner stock requires recalculating the joints, not simply using the listed lengths.
  3. Cut and label the finished parts: 1 Base 36 × 7.25 × 0.75 in (914.4 × 184.15 × 19.05 mm), mark P01; 1 Rear emitter rail 36 × 1.5 × 0.75 in (914.4 × 38.1 × 19.05 mm), mark P02; 2 Riser blocks 3.25 × 1.5 × 1.5 in (82.55 × 38.1 × 38.1 mm), mark P03; 1 Front cup stop 36 × 1.5 × 0.75 in (914.4 × 38.1 × 19.05 mm), mark P04. Keep saw kerf outside each finished line. Rip only where the finished width is narrower than the actual stock; use a suitable guide and target ±1/16 in (1.6 mm) for ordinary cuts. Dowel triples mean length × diameter × diameter, not square dowel stock.
  4. Locate the two risers at x = 1 to 2-1/2 and 33-1/2 to 35 in, both y = 5-3/4 to 7-1/4 in on the wider base. Fasten each from beneath with four #8 × 1-1/2 in screws. Their top faces are z = 4 in.
  5. Set the emitter rail lower edge on the two riser tops at z = 4 in, with rear face flush at y = 7-1/4 in. Its front face is y = 6-1/2 in. Drill two vertical pilots per riser through the 1-1/2 in-high rail into its end and install four #8 × 2-1/2 in screws. Keep rail and base screw paths separate.
  6. Attach the front cup stop along y = 0 with six 1-1/4 in underside screws. Its 1-1/2 in height retains cups without hiding their upper rims.
  7. Mark eight cup centers at x = 2-1/4, 6-3/4, 11-1/4, 15-3/4, 20-1/4, 24-3/4, 29-1/4 and 33-3/4 in, all at y = 3-1/2 in. Use cup outside diameter no greater than 3-1/2 in and height no greater than 3 in; do not infer capacity from diameter.
GA-027 dimensioned parts or elevation
  1. Attach removable matched-tubing clips to the rear rail at each x center. Route a short compatible flexible tube forward from the rail front y = 6-1/2 in to discharge above cup-center y = 3-1/2 in, respecting its minimum bend radius. Secure against wandering without kinks; set outlet at least 1/2 in above the actual cup rim, with a reference discharge height z = 4-1/4 in for a 3 in-tall cup.
  2. Set all eight actual cups on the marked centers on a level waterproof outdoor surface. At maximum 3-1/2 in diameter, cup edges remain 1 in behind the front stop, 1/2 in ahead of the riser faces and at least 1/2 in inside the base ends. Verify these clearances and stable flat bases before adding water; no cup may touch the wood stops or risers.
  3. Connect only the irrigation test line, with the actual filter, regulator and water source appropriate to that system. Keep roof water tests separate and label them nonpotable; use it only for inedible landscape applications.
  4. Run the chosen common test duration, stop flow together and compare captured volumes. Repeat a suspicious result after swapping cups; do not label the fixture as a calibrated flowmeter or select watering duration from this comparison alone.
  5. Complete the acceptance checks below before putting the assembly into service. Record any changed stock thickness, fastener or equipment fit on the project sheet. The published geometry has not been physically built or load-tested.

Checks

Operation

Cleaning and maintenance

Primary context

These sources inform the context and do not endorse the original construction design.