Garden · GA-057

Two-sided nonpotable supply flag

Place a durable physical warning at an outdoor nonpotable supply without hanging a tag from a valve handle.

Editorial construction draft. Original digital diagrams; no physical build or load certification. Read dimensions, fit and use limits before making changes. US customary dimensions control; metric values are references.

Before marking and cutting

Use limits

Materials and cuts

PartQtySize to cutMaterial
P01 Warning plate112 × 8 × 1/2 in
304.8 × 203.2 × 12.7 mm
measured 1/2 in plywood exterior-bond plywood for protected non-food-contact fixtures; substitute thickness only by recalculating joints
P02 Upright132 × 1 1/2 × 1 1/2 in
812.8 × 38.1 × 38.1 mm
2 × 2 in board sound untreated wood
P03 Cross foot118 × 3 1/2 × 3/4 in
457.2 × 88.9 × 19.05 mm
1 × 4 in board sound untreated cedar or other durable untreated wood
P04 Second foot114 × 3 1/2 × 3/4 in
355.6 × 88.9 × 19.05 mm
1 × 4 in board sound untreated cedar or other durable untreated wood

Hardware and consumables

Tools

Assembly

GA-057 dimensioned assembly
  1. Plan the two-sided nonpotable supply flag for this result: Place a durable physical warning at an outdoor nonpotable supply without hanging a tag from a valve handle. Confirm the design reference before cutting: Message legible on both sides; plate screws buried. In the drawings x runs left to right, y runs front to rear and z runs upward.
  2. Verify the required stock before laying out these parts: 1 × 4 in board: actual 0.75 × 3.5 in (19.05 × 88.9 mm); 2 × 2 in board: actual 1.5 × 1.5 in (38.1 × 38.1 mm); measured 1/2 in plywood: measured thickness 0.5 in. Reject split or twisted wood and unknown salvage; thinner stock requires recalculating the joints, not simply using the listed lengths.
  3. Cut and label the finished parts: 1 Warning plate 12 × 8 × 0.5 in (304.8 × 203.2 × 12.7 mm), mark P01; 1 Upright 32 × 1.5 × 1.5 in (812.8 × 38.1 × 38.1 mm), mark P02; 1 Cross foot 18 × 3.5 × 0.75 in (457.2 × 88.9 × 19.05 mm), mark P03; 1 Second foot 14 × 3.5 × 0.75 in (355.6 × 88.9 × 19.05 mm), mark P04. Keep saw kerf outside each finished line. Rip only where the finished width is narrower than the actual stock; use a suitable guide and target ±1/16 in (1.6 mm) for ordinary cuts. Dowel triples mean length × diameter × diameter, not square dowel stock.
  4. Place the warning plate centered across the upright, with its lower edge 24 in above the post bottom (installed z = 24-3/4 in).
  5. Pilot four front-entry plate holes into the upright, two at z = 26 and two at z = 30 in, spaced across the 1-1/2 in post face without splitting it.
  6. Fasten with four 1-1/2 in screws, keeping tips inside the post. Seal/finish the non-food-contact wood for outdoor exposure as the finish label directs.
GA-057 dimensioned parts or elevation
  1. Lay out a 3-1/2 in-wide × 3/8 in-deep half-lap at the center of each foot: x = 4-1/4 to 7-3/4 in on the long foot; y = -3/4 to 2-3/4 in on the cross foot in the drawing coordinates. Cut one lap from the upper face and its mate from below, then dry-fit them into a flat 3/4 in-thick cross.
  2. Seat the post bottom on the foot cross at z = 3/4 in. Predrill and drive four 3 in screws upward through the crossed feet into the post end, using a small staggered square pattern inside its 1-1/2 in face. Check that both feet lie flat after tightening.
  3. On both sides apply the exact high-contrast words NONPOTABLE WATER / DO NOT DRINK. Keep letters large and leave no decorative texture behind them.
  4. Place beside the actual supply where the message is visible before the outlet is operated. Add separate low restraints and keep the feet away from the walking route.
  5. Check visibility from both approach directions. The flag complements identification; it does not provide backflow protection, pipe separation, a locked lid or compliance with local labeling rules.
  6. Complete the acceptance checks below before putting the assembly into service. Record any changed stock thickness, fastener or equipment fit on the project sheet. The published geometry has not been physically built or load-tested.

Checks

Operation

Cleaning and maintenance

Primary context

These sources inform the context and do not endorse the original construction design.