CL-003 Quick-release curtain side-return sealing wings

Make a pair of narrow hinged side panels that close the wall-to-curtain side gap but open by hand for curtain service.

Limits and intended use

Materials and cuts

PartQtyFinished inches and millimetersMaterial
P01 Wall strips236 x 1 1/2 x 3/4 in
914.4 x 38.1 x 19.05 mm
sound untreated cedar or other durable untreated wood; no unknown salvage
P02 Side-return leaves236 x 4 x 1/4 in
914.4 x 101.6 x 6.35 mm
smooth plywood for indoor dry fixtures only
P03 Hinge backing battens236 x 1 1/2 x 3/4 in
914.4 x 38.1 x 19.05 mm
sound untreated cedar or other durable untreated wood; no unknown salvage

Hardware and purchased components

Tools

Step-by-step assembly

  1. Inspect sound stock and a stable work surface. In the drawings x runs left to right, y front to rear and z upward.
  2. Measure actual stock before cutting; nominal board names are not finished cross sections. Match each part to its label and material in the cut schedule.
  3. Mark each finished cut separately, leaving saw kerf outside the line. Label parts, target +/-1/16 in and ease all hand-contact edges.
  4. Plan one wing at each curtain side. The shown two-wing layout has 27-1/2 in total separation on the drawing for clarity, not a required window width. Each leaf is 36 in high and 4 in deep; the actual mounting location is chosen so the leaf softly meets the curtain edge without crushing it.
  5. Place a 36 in backing batten along one vertical edge of each 1/4 in leaf. Predrill six holes through the plywood at heights 2,8,14,22,28 and 34 in, centered over the batten. Fasten with 3/4 in screws, leaving at least 1/4 in of wood above each screw point.
  6. Fit three 4 in hinge segments along each reinforced edge, centered at heights 6,18 and 30 in. Keep the hinge pin outside the leaf edge so the panel can swing toward the room. Hinge leaves land on the wood batten, never on unsupported 1/4 in plywood alone.
  7. Join each hinge to its 1-1/2 in wall strip with short screws selected from the actual hinge pattern. The listed 24 screw allowance assumes four per segment; change the purchase count if the chosen hinge has more holes. Recess no hardware into the flexible curtain fabric.
  8. Mount both wall strips to verified sound wood or an appropriate substrate, at the measured curtain sides. Install at least three fixings per strip, with the actual anchor type and embedment recorded. Do not mount to a glazing bead or a window sash.
  9. Set one low-force magnetic catch at the top of each wing to locate its normal closed position. Fasten the matching plate through the reinforced leaf edge. Put a 6 in folded pull tab under the plate screws, with a loop large enough for fingers but no long hanging cord.
  10. Swing each wing closed until the plain outer leaf edge meets the curtain lightly. Sand a sharp corner and add a removable felt edge if necessary. Open and close the curtain; neither wing may capture or fray its fabric. A wing must release with one hand.
  11. Check window access and any required escape path from inside. These wings are thermal side returns, not locks or security devices. Open them whenever they interfere with ventilation or the window; inspect behind the curtain for dampness during cold weather.
  12. Complete the listed acceptance checks before use. Record changes to stock or fittings; retain this sheet with the finished assembly.
CL-003 plan dimensioned construction drawingCL-003 front dimensioned construction drawing

Acceptance checks

Cleaning and maintenance

Primary context

Primary references support context only. Design geometry, cut schedule, assembly and drawings are original editorial work, not certified or endorsed by the named agencies.