Separate broad loose leaves from a small attended nonpotable stream: water drops through an inclined slotted sheet into a lower lined channel while rejected leaves and a blinded-screen bypass leave over a higher apron.
Original small open-to-atmosphere apparatus for attended cold nonpotable service. No mains connection, elevated tank, treatment efficacy, output rate or pressure/load rating is specified. Unbuilt / untested. US customary dimensions control.
| Part | Quantity | Actual dimensions | Material / special cut |
|---|---|---|---|
| A Rebated outer cheek with integral curb | 2 | 30 in x 10 1/2 in x 3/4 in 762.0 x 266.7 x 19.05 mm | Flat exterior-bond birch plywood, actual listed thickness, no voids or sharp exposed edges; seal and cure exposed wood before liner fitting. Outer-quarter YZ profile: (0,0),(30,0),(30,4.25),(23.5,4.25),(23.5,4.690196),(0,10.5) in. Rebate the INNER1/2 in thickness to the lower seat profile (0,0),(30,0),(30,2.875),(23.5,2.875),(23.5,3.440196),(0,9.25). The outer 1/4 in thickness remains as the integral side curb. |
| B Underflow floor | 1 | 30 in x 14 in x 3/4 in 762.0 x 355.6 x 19.05 mm | Flat exterior-bond birch plywood, actual listed thickness, no voids or sharp exposed edges; seal and cure exposed wood before liner fitting. Square ends. Faces x=0-14, y=0-30, z=0-3/4 in in the fabrication pose. |
| C Machined coarse screen | 1 | 25 in x 14 7/8 in x 1/4 in 635.0 x 377.825 x 6.35 mm | Virgin solid HDPE sheet, machine to the listed actual thickness; nonpotable cold service only. No welding or solvent joint assumed. Length 25 in follows the slope, not its horizontal projection. Fifteen crosswise capsule slots: local Y center 1.5+1.5 j in for j=0..14; slot X limits 1.4375-13.4375 in and width 3/8 in. End radii 3/16 in; centers X 1 5/8 and 13 1/4 in. Original slot sheet, not purchased unspecified mesh. |
| D Upper reject apron | 1 | 6 in x 14 7/8 in x 1/4 in 152.4 x 377.825 x 6.35 mm | Virgin solid HDPE sheet, machine to the listed actual thickness; nonpotable cold service only. No welding or solvent joint assumed. Fits between the integral curbs at x=-7/16-14 7/16 in,y=24-30 in, underside z=2 7/8 in. The sloping screen overlaps it without sharing a fastener. |
| E One unseamed underflow liner | 1 | 32 in x 20 in x 0.045 in 812.8 x 508.0 x 1.143 mm | Elevate PondGard W56PL40801A raw EPDM liner stock, nominal 0.045 in / 1.143 mm; manufacturer +10/-20% thickness range 0.036-0.0495 in. Measure actual sheet; no generic roofing rubber substitution. One rectangle; length along Y. Do not cut floor or corner slits. Form a shallow open-ended U over the padded 14 in floor, then clamp only the upper side margins. Nominal material thickness is not a machined gauge. |
| F Soft liner-contact underlay | 1 | 32 in x 20 in x 1/8 in 812.8 x 508.0 x 3.175 mm | New clean nonwoven polyester liner underlay, measured compressed thickness 1/8 in, compatible with the selected EPDM; no oil, adhesive foam or abrasive scrap. One rectangle matching E. Keep it flat on the floor and up the two side faces; no folded lumps under the screen or liner clamps. |
| G Inside liner clamping strip | 2 | 30 in x 3/4 in x 3/8 in 762.0 x 19.05 x 9.525 mm | Clear straight-grained cedar, actual 3/8 in thick, rounded liner edges, exposed finish fully cured. Length along Y, height 3/4 in. Reference z=1 3/4-2 1/2 in; lower than the apron underside. Actual inward X offset equals the measured underlay plus membrane stack. |
| H Front fall-setting foot | 1 | 16 in x 3/4 in x 1/2 in 406.4 x 19.05 x 12.7 mm | Clear straight-grained cedar, actual 1/2 in thick; no loose stacked shims. Length along X, center under B at y=0-3/4 in. Attach beneath B; rear cheek edges rest on the same level ground. |
Rule, square, marking gauge, calipers, depth-stop drill/driver, backed jigsaw or coping saw, countersink, files, sanding blocks, clamps and scissors reserved for liner. Special tools and drill diameters are stated in the steps.
x left/right; y along the apparatus; z upward. Fabrication datum and any separate operating tilt are stated in steps.
Retained segments with the same part/instance belong to one machined stock piece, not additional parts. Positions and sizes below are US inches; rotations are degrees.
| Part / instance | Origin x,y,z | Size / rotation |
|---|---|---|
| A / 1 | [-0.75, 0, 0] | [0.25, 30, 10.5] / [0, 0, 0] |
| A / 1 | [-0.5, 0, 0] | [0.5, 30, 9.25] / [0, 0, 0] |
| A / 2 | [14, 0, 0] | [0.5, 30, 9.25] / [0, 0, 0] |
| A / 2 | [14.5, 0, 0] | [0.25, 30, 10.5] / [0, 0, 0] |
| B / 1 | [0, 0, 0] | [14, 30, 0.75] / [0, 0, 0] |
| C / 1 | [-0.4375, 0, 9.25] | [14.875, 25, 0.25] / [-13.88654036262899, 0, 0] |
| D / 1 | [-0.4375, 24, 2.875] | [14.875, 6, 0.25] / [0, 0, 0] |
| E / 1 | [-2.5, -1, 0.875] | [20, 32, 0.045] / [0, 0, 0] |
| F / 1 | [-2.5, -1, 0.75] | [20, 32, 0.125] / [0, 0, 0] |
| G / 1 | [0.17, 0, 1.75] | [0.375, 30, 0.75] / [0, 0, 0] |
| G / 2 | [13.455, 0, 1.75] | [0.375, 30, 0.75] / [0, 0, 0] |
| H / 1 | [-1, 0, -0.5] | [16, 0.75, 0.5] / [0, 0, 0] |
Cold nonpotable service water only. Never drink, cook, wash food, irrigate edible parts or supply animals from this apparatus.
An open coarse separator is not a microbial filter, disinfection device or mosquito barrier. Drain and dry after the attended session; do not leave an open stored-water habitat.
This design is not a storm-drain, structural or flood-control installation. Stop at backup, bypass outside the intended catch area, a loose joint or a damaged membrane.
Stop input before brushing the slots. Lift out broad debris; do not ram a rod through the slot and membrane below.
After each session drain both open ends, remove C when needed, and wipe the liner over soft backing. Follow the membrane maker cleaning guidance; isolate petroleum/oils and abrasive cleaners.
Inspect every capsule bridge for a crack, the eight screen holes for elongation, and G for loose edges. Replace a damaged screen or punctured membrane; do not hide damage with unverified sealant.
After drying, store under cover with no weight on C. Recheck the falling lap and contained screw tips whenever a liner, washer or wood piece is replaced.
All positions use a dry fabrication datum before H produces the small operating fall. The whole rigid frame tilts together; no moving joint or water container is suspended.
E/F scene entries are flat-stock references only. Their installed U section is shown in plate 3; they are flexible sheets, not flat blocks left across the open channel.
The nominal membrane thickness 0.045 in is preserved as a decimal; actual manufacturer range 0.036-0.0495 in and compressible underlay make clamp X coordinates reference values. Floor clear width remains more than 13 in at the reference stack.
A coarse slot sheet cannot intercept dust, dissolved chemicals or microorganisms and cannot seal a receiving reservoir against insects. This apparatus ends in an open free discharge and does not alter a building drain.
Rutgers Cooperative Extension: Rain Barrels Part II: Installation and Use, FS1118 Source
Elevate / Amrize: PondGard Rubber Liners, TIS101, August 20, 2025 Source
Elevate / Amrize: PondGard EPDM Design and Installation Guide, July 2025 Source