WA-005 Guided float flag for a shallow service-water pan

Display two checked low/high water references above an opaque, shallow nonpotable service pan using a buoyant mechanical follower.

Original attended, open-pan level indicator. No fill valve, pressure vessel, potable treatment, certified depth accuracy or automatic overflow protection is built. Actual receiver fit, complete wet mass, low guide drag and water-reference comparisons are required. The apparatus is unbuilt and untested. Unbuilt / untested. US customary dimensions control.

Before cutting

Materials and actual cuts

PartQuantityActual dimensionsMaterial / special cut
A Fully supported base board124 in x 20 in x 3/4 in
609.6 x 508.0 x 19.05 mm
Sound flat exterior-bond plywood or straight-grain hardwood, finished to the listed actual size. No voids, splits or loose fibers. The base remains fully supported; no elevated tank or bench load rating is claimed. Global X 0..24, Y 0..20, Z 0...75. Keep the entire underside supported on a level bench or floor. WB1 axes: X 11, 11.75, 12.5, 13 at Y 18.375. WB3 axes: X 10.8125/13.1875, Y 19.125. Countersink underside heads fully flush.
B Rear mast118 in x 3 1/2 in x 3/4 in
457.2 x 88.9 x 19.05 mm
Sound flat exterior-bond plywood or straight-grain hardwood, finished to the listed actual size. No voids, splits or loose fibers. The base remains fully supported; no elevated tank or bench load rating is claimed. Install X 10.25..13.75, Y 18..18.75, Z .75..18.75, with grain along its 18 in height. Transfer every F-dependent arm/wedge row from the actual received pan floor. Do not assume the illustrative F = 1 in is the pan interior.
C Rear mast-foot gusset24 in x 1 1/4 in x 3/4 in
101.6 x 31.75 x 19.05 mm
Sound flat exterior-bond plywood or straight-grain hardwood, finished to the listed actual size. No voids, splits or loose fibers. The base remains fully supported; no elevated tank or bench load rating is claimed. Retain one right triangle in YZ: (18.75,.75), (20,.75), (18.75,4.75). X intervals 10.25..11 and 13..13.75. The finished part is triangular, not the full rectangular blank.
D Lower split-guide arm18 1/4 in x 1 1/2 in x 3/4 in
209.55 x 38.1 x 19.05 mm
Sound flat exterior-bond plywood or straight-grain hardwood, finished to the listed actual size. No voids, splits or loose fibers. The base remains fully supported; no elevated tank or bench load rating is claimed. Install X 11.25..12.75, Y 9.75..18, Z F+6.5..F+7.25. At the front face remove the guide half-notch: X 12 +/- .140625, Y 9.75..9.890625, through Z. WB4 rear axes X 11.75/12.25, Z F+6.875.
E Upper guide and scale arm18 1/4 in x 3 1/2 in x 3/4 in
209.55 x 88.9 x 19.05 mm
Sound flat exterior-bond plywood or straight-grain hardwood, finished to the listed actual size. No voids, splits or loose fibers. The base remains fully supported; no elevated tank or bench load rating is claimed. Install X 11.25..14.75, Y 9.75..18, Z F+9.5..F+10.25. Same guide half-notch as D. WB4 axes X 11.75/12.25, Z F+9.875. Fixed scale clamp SF1 axes: X 14, Y 10.25/10.75.
F Removable front guide cap21 1/2 in x 3/4 in x 3/4 in
38.1 x 19.05 x 19.05 mm
Sound flat exterior-bond plywood or straight-grain hardwood, finished to the listed actual size. No voids, splits or loose fibers. The base remains fully supported; no elevated tank or bench load rating is claimed. Two matched caps, X 11.25..12.75, Y 9..9.75, at Z F+6.5 and F+9.5. The rear half-notch is X 12 +/- .140625, Y 9.609375..9.75, through Z. Together with the arm it forms a true 9/32 in square guide. WB7 axes X 11.5/12.5 at guide bottom + .375, directed along +Y.
G Arm underside support wedge23 in x 2 in x 1 1/2 in
76.2 x 50.8 x 38.1 mm
Sound flat exterior-bond plywood or straight-grain hardwood, finished to the listed actual size. No voids, splits or loose fibers. The base remains fully supported; no elevated tank or bench load rating is claimed. Lower YZ triangle: (15,F+6.5), (18,F+6.5), (18,F+4.5); upper triangle 3 in higher. Both occupy X 11.25..12.75. Vertical WB6 axes X 11.5/12.5, Y 17.25. Horizontal WB5 axes X 11.75/12.25, Z F+5.875 or F+8.875. Different X rows prevent hidden screw crossings.
H Float capture plate23 in x 3 in x 1/8 in
76.2 x 76.2 x 3.175 mm
Solid unfilled HDPE, such as King StarBoard standard material machined from oversize stock to the actual gauge. No foamed core, adhesive joint or transferred food-contact certification. Both 3 in square, actual thickness .124..126 in, centered X 12, Y 9.75 in the reference pose. Four received .125..126 in bores at local X/Y .375 or 2.625. Do not countersink: rounded MF1 heads seat below the lower plate. Upper H also has two mount bores at local X 1.5, Y 1.25/1.75.
I Closed-cell buoyancy core13 in x 3 in x 2 in
76.2 x 76.2 x 50.8 mm
One monolithic closed-cell crosslinked PE foam block, Plastazote LD45 candidate. Published data are typical only; actual finished dimensions and complete wet moving mass govern. Receive one monolithic closed-cell block, plan 2.995..3.005 in square and thickness 1.995..2.005. Four 9/32 in square through-passages on the H corner pattern. TOP ONLY: two 7/16 in diameter reliefs .500 +/- .001 in deep, at local (1.5,1.25)/(1.5,1.75). The lower foam section remains intact. Actual core height must not exceed the shortest J spacer; trim before assembly. No laminated or open-cell substitution.
J Compression-limiting square spacer42 in x 1/4 in x 1/4 in
50.8 x 6.35 x 6.35 mm
Solid unfilled HDPE, such as King StarBoard standard material machined from oversize stock to the actual gauge. No foamed core, adhesive joint or transferred food-contact certification. Finish four equal 2.000 +/- .001 in lengths, each .25 in square. Make a straight .125..126 in axial bore. They fit the larger foam passages and span the two H inside faces, so screw tightening stops on solid spacer ends rather than compressing the foam.
K Slotted root/scale capture block21 1/2 in x 3/4 in x 1/2 in
38.1 x 19.05 x 12.7 mm
Solid unfilled HDPE, such as King StarBoard standard material machined from oversize stock to the actual gauge. No foamed core, adhesive joint or transferred food-contact certification. Two blocks, each 1.5 X by .75 Y by .5 Z. Centered top pocket: target 1.253 X by .253 Y, depth .375; received length 1.252..1.254, width .252...254, depth .374...376. Nominal pocket X .1235..1.3765, Y .2485...5015; leave the .125 nominal floor. Square the corners. Side-pin bores .125...126 along Y at local X .375/1.125, Z .3125. Vertical mount bores .125...126 at local X .75, Y .125/.625. Mounts and side pins use separate axes.
L One-piece follower stem and flag111 1/2 in x 1 1/2 in x 1/4 in
292.1 x 38.1 x 6.35 mm
Solid unfilled HDPE, such as King StarBoard standard material machined from oversize stock to the actual gauge. No foamed core, adhesive joint or transferred food-contact certification. One retained XZ profile, all .249...251 in thick in Y. Relative to stem axis X 0 and root bottom Z 0, vertices: (-.625,0),(.625,0),(.625,.5),(.125,.5),(.125,8.25),(.875,8.25),(.875,8.5),(.125,8.5),(.125,11.5),(-.125,11.5),(-.125,.5),(-.625,.5). Straight stem width .249...251; root width 1.249..1.251. Root pin holes .125...126 along Y at X +/- .375, Z .1875. Temporary test-loop hole 3/32 in along Y at X 0, Z 11.25. The LOWER flag edge is the only reading edge. Root bottom square to the stem within .002 in over a 1 in reference.
M Blank fixed reference blade17 in x 1 1/4 in x 1/4 in
177.8 x 31.75 x 6.35 mm
Solid unfilled HDPE, such as King StarBoard standard material machined from oversize stock to the actual gauge. No foamed core, adhesive joint or transferred food-contact certification. Bottom square to blade axis within .002 in over 1 in; whole straightness within .002 in. Actual blade 7 Z by 1.25 X by .25 Y; receive width 1.249..1.251, thickness .249...251. Install X 13.375..14.625, Y 10.375..10.625, Z F+10.375..F+17.375. Two .125...126 in side-pin bores at local X .25/1.0, Z .1875. Lower .375 in enters K. Mark actual LOW/HIGH bands after qualification; no pre-calibrated ruler is supplied.

Hardware and tools

US rule with 1/64 in divisions; calipers and depth gauge readable to .001 in; square and straightedge; .001 in feeler; straight 1/4 in square setup bar; clamped wood saw/drill; router or mill and square files for the HDPE pockets; 3/32, 1/8, 7/64, 3/16 and 13/64 in bits; countersink; small wrenches and 3/32 in hex key; suitable force balance and known reference; plain water, independent depth rule and water-resistant marking crayon. Complete receiving dimensions and repeated water trials govern.

Measured assembly reference

x left/right; y along the apparatus; z upward. Fabrication datum and any separate operating tilt are stated in steps.

Retained segments with the same part/instance belong to one machined stock piece, not additional parts. Positions and sizes below are US inches; rotations are degrees.

Part / instanceOrigin x,y,zSize / rotation
A / 1[0, 0, 0][24, 20, 0.75] / [0, 0, 0]
B / 1[10.25, 18, 0.75][3.5, 0.75, 18] / [0, 0, 0]
C / 1[10.25, 18.75, 0.75][0.75, 1.25, 4] / [0, 0, 0]
C / 2[13, 18.75, 0.75][0.75, 1.25, 4] / [0, 0, 0]
D / 1[11.25, 9.75, 7.5][1.5, 8.25, 0.75] / [0, 0, 0]
E / 1[11.25, 9.75, 10.5][3.5, 8.25, 0.75] / [0, 0, 0]
F / 1[11.25, 9, 7.5][1.5, 0.75, 0.75] / [0, 0, 0]
G / 1[11.25, 15, 5.5][1.5, 3, 2] / [0, 0, 0]
F / 2[11.25, 9, 10.5][1.5, 0.75, 0.75] / [0, 0, 0]
G / 2[11.25, 15, 8.5][1.5, 3, 2] / [0, 0, 0]
H / 1[10.5, 8.25, 1.75][3, 3, 0.125] / [0, 0, 0]
H / 2[10.5, 8.25, 3.875][3, 3, 0.125] / [0, 0, 0]
I / 1[10.5, 8.25, 1.875][3, 3, 2] / [0, 0, 0]
J / 1[10.75, 8.5, 1.875][0.25, 0.25, 2] / [0, 0, 0]
J / 2[10.75, 10.75, 1.875][0.25, 0.25, 2] / [0, 0, 0]
J / 3[13.0, 8.5, 1.875][0.25, 0.25, 2] / [0, 0, 0]
J / 4[13.0, 10.75, 1.875][0.25, 0.25, 2] / [0, 0, 0]
K / 1[11.25, 9.375, 4.0][1.5, 0.75, 0.5] / [0, 0, 0]
K / 2[13.25, 10.125, 11.25][1.5, 0.75, 0.5] / [0, 0, 0]
L / 1[11.375, 9.625, 4.125][1.5, 0.25, 11.5] / [0, 0, 0]
M / 1[13.375, 10.375, 11.375][1.25, 0.25, 7] / [0, 0, 0]

Numbered assembly

  1. Choose a level, fully supported 24 x 20 in work area with at least 32 in of clear height for the mast and temporary force-balance suspension. This apparatus shows two water references above an opaque service pan. It does not stop filling or detect an overflow automatically. Read the complete receiving, machining, force-check, calibration and service sequence. No physical build or qualification test has been performed by the author.
  2. Receive the real FG334900GRAY before positioning the arms. Center its outer footprint at X 12, Y 9.5 on A. Require outer length <= 20.0625, width <= 15.0625 and height <= 5.0625 in; no handle or rib may extend behind Y 17.03125. Verify a continuous interior service corridor X 9.25..14.75, Y 4.5..12.5, from its highest floor through 5.125 in above that floor. This is 5 1/2 in wide by 8 in long. It includes the operating float and its forward service translation. Outer dimensions do not prove the interior. Reject an incompatible pan; do not heat, cut or guess its shape.
  3. With the empty pan in that position, measure F: the highest floor point anywhere in the service corridor, from A underside Z 0. Use a straight rim bridge and depth gauge if needed; subtract the measured interior depth from its measured absolute reference height. F must be .875..1.125 in. The lowest rim must be at least 4.25 in above F. Transfer this ACTUAL datum to the mast. Illustrations use F = 1 in only. Never use the lip as zero or infer F from the published 5 in outer height. ALL floating b+... heights below are above F, so global Z = F+b+.... Drawing 04 uses local z = 0 at bottom H underside.
  4. Finish A and B to the actual cuts; put B grain along its 18 in height. Retain the two C right triangles, not their rectangular blanks. Keep finished wood gauges within .001 in of the listed values and mating faces flat. Prove each wood-screw pilot on an offcut of the actual stock. The stated 7/64 in pilot is a starting size for received stock; change the pilot if an offcut splits or fails to seat, without changing the screw axes or lengths.
  5. Clamp B at X 10.25..13.75, Y 18..18.75 with its bottom at Z .75. Install four WB1 from the underside of A at X 11/11.75/12.5/13, Y 18.375. Heads finish flush at Z 0, tips Z 2.5. Confirm both mast planes are square and its top is Z 18.75. A must remain fully supported across its underside; it is not a platform spanning supports.
  6. Fit C behind B at Y 18.75..20. Install WB2 from mast front Y 18, at X 10.4375/13.5625 and Z 1.375/2.375, to tips Y 19.25. Install WB3 vertically from A underside at X 10.8125/13.1875, Y 19.125, to tips Z 1.5. These different X rows prevent the vertical and horizontal screws crossing inside the gussets. Check tips against the actual triangular profile before driving.
  7. Cut D, E and their two matched caps F. Clamp each cap to its own arm at the Y 9.75 split. Make a true 9/32 in square vertical guide centered X 12, Y 9.75: each half is 9/64 in deep in its mating Y face. Square-file the corners. Receive actual guide sides .28125...28325 in. Do not use a round hole for a square stem. Mark LOWER and UPPER pairs and keep guide walls smooth and unpainted.
  8. Transfer measured F to the arm underside heights F+6.5 and F+9.5. Both rear arm ends butt mast front Y 18. Install WB4 from mast back Y 18.75, at X 11.75/12.25 and Z F+6.875/F+9.875, to tips Y 16.25. Those X axes are deliberately offset from vertical WB6. Keep arms level and guides aligned; these end-grain screws alone are not the finished arm support.
  9. Cut both G wedges to the actual 3 Y by 2 Z triangles. They occupy X 11.25..12.75, Y 15..18 below the arms. Install WB5 at X 11.75/12.25, Z F+5.875/F+8.875, from mast back Y 18.75 to tips Y 16.25. Install vertical WB6 at X 11.5/12.5, Y 17.25, from arm top to tips F+5.75/F+8.75. Verify the full wedge and every received pan rim/handle remain at least 1/8 in apart.
  10. Replace each matched F with WB7 from Y 9 to Y 11.25 at X 11.5/12.5 and the guide midheight. Pass a straight, actual 1/4 in square setup bar through both guides without bending it or spreading a cap. Locate both guide centers within .002 in of X 12, Y 9.75; their relative X/Y difference must also be <= .002 in per axis. Caps must come off forward with screwdriver access clear of the pan. Correct misalignment rather than enlarging a guide beyond .28325 in.
  11. Machine both K blocks. Their centered rectangular pockets target 1.253 x .253 x .375 in deep; receive length 1.252..1.254, width .252...254 and depth .374...376. Square the internal corners and retain the nominal .125 in floor. Make the two side-pin bores at local X .375/1.125, Z .3125, along Y; make the separate vertical mount bores at local X .75, Y .125/.625. Receive these bores .125...126. The close pocket fit limits rocking; the two side pins alone are not treated as a perfectly rigid joint.
  12. Put fixed K on E at X 13.25..14.75, Y 10.125..10.875, Z F+10.25..F+10.75. Install cylindrical socket-cap SF1 at X 14, Y 10.25/10.75; under-head at F+10.75 and tips F+9.0. Put their washers/nuts beneath E. Both washers need full support on E. Seat M on the pocket floor, giving its lower edge F+10.375. Fit SF2 at X 13.625/14.375, Z F+10.5625, from Y 10.125 to tips 11.125. Retain at least .050 in of complete thread beyond every insert.
  13. Cut L as one piece from .249...251 in thick HDPE using its full XZ contour. Do not glue on a pointer or root. The lower flag edge, local Z 8.25, is the reading edge. Receive root width 1.249..1.251 and stem width .249...251. The stem must remain within .002 in of a common straight line over its length; check with a straightedge and feeler. Root bottom must be square to the stem within .002 in over a 1 in reference. Make the two .125...126 root holes and the 3/32 in temporary loop hole at their listed centers.
  14. Cut both H plates to actual .124...126 in thickness. Match four .125...126 corner bores on a 2.25 in square pattern, each .375 in from adjacent edges. The lower plate is NOT countersunk: MF1 rounded heads sit below it. Add upper H mount bores at local X 1.5, Y 1.25/1.75. Keep hole-center errors within .001 in per axis. Distinguish this small center mount pattern from the corner ties.
  15. Finish the monolithic I core within its plan and thickness ranges. Make four 9/32 in square clearance passages on the corner tie axes. From TOP ONLY make two 7/16 in diameter reliefs .500 +/- .001 in deep at local (1.5,1.25)/(1.5,1.75). They clear complete mount nuts, washers and tips, not just a bolt centerline. The lower foam zone stays intact except for the four passages. Receive or trim I so its actual height is no greater than the shortest J spacer; do not obtain the hard-stop gap by compressing an oversized core. Do not laminate scraps or use open-cell foam.
  16. Finish all four J spacers to 2.000 +/- .001 in with square, parallel ends; bore them .125...126 along their lengths. Confirm the received .104...112 in screw shafts pass freely. The .25 in square spacers slip through their larger foam passages. Four equal solid lengths, not tightening torque or an assumed foam compression, set the separation between H inside faces.
  17. Before fitting I, install moving K on upper H, centered on float X 12, Y 9.75. Use MF2 at local X 0, Y +/- .25, under-head b+2.75 to tips b+1.75. Only cylindrical heads <= .185 in OD and <= .115 in high are accepted here; wider pan/button heads can touch the root. Washers/nuts beneath H enter the foam reliefs with the screw tips. Tighten to full flat seating without bowing H; a .001 in feeler must not enter the K/H bearing joint. Check the assembly after wet qualification as well.
  18. Stack lower H, the four J spacers and I, then the prepared upper H. Insert MF1 upward with rounded heads against lower H underside b; tips are b+2.75. Add one received washer and locknut per corner. The nominal solid stack is .125+2+.125 = 2.25 in. Nip diagonally only until all four spacer ends contact both plates. Do not compress foam to hide unequal spacers. No sharp thread projects below H; head height is <= 5/64 in. Before tightening, align the moving K center to the H center within .020 in per X/Y axis. The complete plate-center offset from the stem reference must remain <= .025 in per X/Y axis throughout the captured root play.
  19. Seat L root initially on the moving K floor, nominally b+2.375. Fit both MF3 side pins at local X +/- .375, Z b+2.5625, from Y -.375 to +.625 relative to float center. Seat washers/nuts flat without bending the stem or crushing the fork. Before and after assembly, pocket maximum length/width must remain 1.254/.254; the root must move by no more than .025 in vertically within the pins. Reduced clearance from gentle seating is acceptable. Before tilt, the complete root hardware stays below F+b+2.93 in GLOBAL Z. Apply the full tilted envelope before checking the lower arm. Its permitted small lift and rocking are included in the envelope calculations; do not assume a zero-play joint.
  20. Weigh the COMPLETE moving unit H/I/J, moving K, L, all eight screws, eight nuts and eight washers, including any absorbed water. Temporarily suspend it from a fine loop through the L tip hole. Actual mass must be 60..110 g. For the specified 300 g/2 g balance, accept free-hanging readings 64..106 g with the stated conservative +/-3 g reading allowance. Check zero/tare and a suitable known reference using the maker procedure; do not recalibrate the spring yourself. Correct wrong stock or hardware instead of deleting retainers to meet the mass limit.
  21. Remove both guide caps with the empty pan on A. Hold the complete float over the received service corridor. Bring the stem sideways into both open main half-notches from the FRONT; replace both matched caps and all four WB7. The broad root and side flag cannot pass through closed square guides. Keep the stem straight and verify the fixed scale is clear. Do not force, cut off or bend a retained contour to obtain assembly access.
  22. With no water, suspend the unit by the temporary balance loop and record free-hanging reading R. Slowly raise/lower through b = .25..3.25 in without pan contact, acceleration or side-pull. Pause at least every 1/4 in and observe breakaway and running readings continuously between pauses. Upward readings must be <= R+4 g; downward readings >= R-4 g. Allowing +/-6 g on each difference bounds equivalent drag by 10 gF. Repeat dry and water-wiped. Correct burrs/alignment rather than forcing movement, adding lubricant or opening guides beyond their received size. These are required builder checks, not tests performed by the author.
  23. Remove the loop and balance. Check the whole attached assembly over its full operating stroke and every permitted guide, pocket and pin play. At LOW, all lower rounded heads must clear the highest floor by >=1/8 in. At HIGH, complete root/nuts/tips must clear the lower arm by >=1/8. Keep the flag >=1/4 above the upper arm and >=1/8 from fixed blade/clamp. Include the actual one-piece contours, close-pocket joint rocking, heads, washers and tips; a foam-only radius check is insufficient.
  24. For initial wet qualification use plain fresh nonpotable water at 40..95 F, without detergents, oil, brine or ingredients. Add by hand around the float. Attend a one-hour exposure at the highest intended depth, 3.5 in above F, then remove through the service path, drain surface droplets and repeat complete mass, wet-stem drag and full-envelope gates. This test has not been performed by the author. The user must qualify the received assembly; stop for swelling, changed mass or drag. Later sessions are attended and limited to 30 minutes, followed by draining and drying.
  25. Use an independent vertical rule to set still water 1.5 in above the actual F datum. Approach from below and from above three times each, without touching the float. Mark all LOWER flag-edge positions on M. The observed spread must be <=3/16 in. Mark LOW at the midpoint of that spread and draw a 3/8 in high band centered there. Do not infer this offset from the foam density or change marks to hide sticking.
  26. Repeat all six rising/falling comparisons at actual 3.5 in above F and mark HIGH. Midpoint spacing must be 2 +/- .1875 in, with both bands entirely on M. Verify >=.75 in freeboard to the actual lowest rim. Repeat the motion and clearances at both extremes. Use the same pan orientation, datum, mass and viewing direction; repeat qualification after a material/hardware change or a significant temperature change. No intermediate-depth accuracy is promised.
  27. Read the LOWER flag edge from straight in front of M at the same eye height used for calibration. LOW and HIGH are the two observed service references, not automatic commands. Inspect the water itself before drawing or adding it, and stop filling at the upper reference. Never connect an unattended mains hose or rely on this flag for overflow protection. Stop for unclear marks, sticking, a changed datum or water outside the intended range.
  28. For service, stop adding water and drain while supporting the whole moving unit by its body, never the flag. Remove both guide caps completely and place them outside the corridor. Initially keep exactly the same square-stem yaw as in the matched closed guides, without twisting in the half-notches, while sliding at least .25 in forward to clear both open half-notches. Hold bottom H at b = .375..3.25 in, plates level within 1/8 in across 3 in, and stem within 1 degree of vertical. Do not twist it from its marked FRONT orientation. Continue until the actual H plate center is at Y 7.125..7.25: a 2.5..2.625 in whole-unit forward translation from Y 9.75. Keep its X center within 1/16 in of X 12. Mark/check this service position on the empty received pan before use. Only then lift the whole unit vertically, clear of both arms, until it is above the pan rim and can move to a separate tray. A 1/4 in stem-only shift frees the notches but does NOT clear the broad float from the arms. Remove the empty pan afterward.
  29. On the tray remove root pins and corner nuts together, keeping matched spacers, cap pairs and plate orientation. Expose all reliefs and foam for inspection and maker-compatible cleaning. Dry everything fully before storage. Replace damaged foam, bent stem, warped plates, loose guides or stripped hardware rather than coating over defects. Reassemble every retainer and repeat actual mass, drag, full motion and both water-reference bands after any rebuild or relocation. No physical performance, life, strength or potable-water certification is claimed.

Checks

Use and maintenance

Plain fresh nonpotable water, 40..95 F, in the received unmodified pan only. No drinking, food contact, detergents, fuels, brine, freezing or hot water.

Only the qualified LOW 1.5 in and HIGH 3.5 in bands are intended. Always check the water itself. No automatic filling, shutoff, overflow alarm or precise intermediate reading is claimed.

Keep A fully supported and pan/frame level. Attend filling and drawing; later qualified sessions last no more than 30 minutes, then drain and dry.

Do not carry a charged pan or frame with the float inside. Use the supported 2.5 in forward side-exit path before vertical removal. The flag is not a lifting handle.

Before use inspect the core, complete hardware, guide walls and marks. Stop for swelling, binding, changed wet mass, rubbing, unclear bands, loose caps or a changed pan/floor reference.

Drain and remove the whole group through the stated cap/translation/lift sequence before lifting the pan or opening the float. Do not pry the T root or flag through a closed guide.

Expose and clean every relief/spacer with the actual material maker instructions; do not rinse a closed charged assembly or use an unknown coating. Dry fully before storage. Replace failed materials instead of hiding damage.

Repeat complete wet mass, drag, motion and both real water-reference bands after changing any material, fastener, cleaning process or pan position. Calculations are conditional geometry and force budgets, not measured reliability, structural rating or physical test results.

Measured interface notes

F is the actual highest floor anywhere in the full service corridor, measured from A underside. Its accepted range is .875..1.125 in. Reference drawings use F = 1 and b = .75 only. b is the actual bottom H center underside above F, not water depth. Every floating b+... height is ABOVE actual F: its global Z from A underside is F+b+.... Drawing 04 local z is measured from bottom H underside. The published pan outer height is never used as its interior floor datum.

The actual 60..110 g moving-mass gate includes both plates, foam, four compression spacers, moving K, L, all eight moving screws/nuts/washers and water pickup. The 10 gF drag allowance includes the conservative instrument-difference budget. Typical foam and HDPE data are material-selection context, not an achieved mass result.

For received geometry, the lower foam waterplane is at least 8.5 in2; 9.1 in2 is a conservative upper bound including the permitted small tilt. Plain 40..95 F water is modeled at 16..16.5 g/in3. Up to .25 g equivalent buoyancy from the four below-plate heads is included in the shallowest-draft bound. Thus draft from bottom H is conditionally between (60-10-.25)/(9.1*16.5) = .33134 and (110+10)/(8.5*16) = .88236 in. These are not observed float depths.

The top-only foam reliefs start 1.5 in above the foam underside; the maximum modeled waterline remains lower. Hard J spacers set the plate separation. No hidden gasket, sealed air box, glued foam or specified leak-tight joint is assumed.

K pockets are close-fitting .252...254 by 1.252..1.254 in. Root-center lift is <=.025 in, and rocking is included. From the seated posture, continuous movement remains on the small-angle contact branch; the root cannot pass 10 degrees while engaged. Even at that provisional angle, .374-.025-hypot(1.251,.251)/2*sin(10 deg) > .23 in of full root section remains below the rim. With that conservative common section, solve w*cos(beta)+.23*sin(beta) <= pocket for each orthogonal projection, not a small-angle tangent approximation. The complete K/H and K/E bearing joints must stay flat within a .001 in feeler check, and root/blade bases must be square to their long axes within .002 over 1 in. Full receiving gates and hardware envelopes are checked separately; no perfectly fixed root is assumed.

The force/lift component of hysteresis is 2*10/(8.5*16) + .025 = .17206 in. This is NOT a bound on total flag-reading spread: guide tilt changes the height of the lateral flag and the long stem, and joint play may change during motion. The actual six-pass spread <=3/16 in at BOTH references is the decisive receiving gate. No wear, temperature, life or intermediate-depth accuracy is certified.

After both guide caps are removed, the whole unit translates 2.5..2.625 in forward before lifting, until the actual H plate center is at Y 7.125..7.25. Initial notch exit preserves the SAME yaw as in its matched closed guides; do not twist the square stem in the half-notches. Later handling holds stem within 1 degree of vertical, plates level within 1/8 over 3 in, and the original FRONT orientation without yawing. This clears the broad float from the main-arm fronts; freeing only the quarter-inch stem does not. The original 5.5 x 8 in received corridor includes that translation and the full float/hardware yaw/tilt envelope.

The original drawings, complete-body envelope audit, export retention and native-page review are documented separately. They establish editorial consistency within explicit receiving limits; they are not a physical prototype, strength, friction, buoyancy or calibration trial.

Measured frame, true triangular supports, whole float position and actual-F transfer. Bought pan shown only as a receiving envelope. Exact base hole layout and actual triangular profiles for both rear mast feet and both arm-support wedges. Actual square half-notch machining, matched caps, complete side-entry path and screw offsets from the follower passage. Matched hard compression spacers, full float/fastener stack, rounded bottom heads and true foam top relief/passages. Actual retained one-piece T-root/stem/flag profile with all bores, single reading edge and matching fixed reference blade. Complete capture-block pocket/bores and separate stationary/moving mount/pin paths including under-plate access. Complete mass/instrument error budgets, conditional buoyancy and actual rising/falling LOW/HIGH qualification without claimed physical tests. Actual whole-float 2.5 in forward translation before vertical lifting, received5.5x8in corridor and controlled body/stem pose.

Primary context

Rubbermaid Commercial Products: FG334900GRAY bus/utility box. Published outer 20 x 15 x 5 in, HDPE and 4.6 gal nominal capacity only. The full interior corridor, floor F, rim and operating fit are original actual receiving gates, not maker-provided internal dimensions. Source

Zotefoams: Plastazote LD45 PIS A013, Issue 1 Revision 1, June 2026. Closed-cell crosslinked PE context and typical density 45 kg/m3 only. Typical material data do not prove complete wet moving mass, life or actual buoyancy. Source

King Plastic: King StarBoard standard material sheet. Standard HDPE material context and typical density .955 g/cc. Nominal sheet gauges do not satisfy the original precision machining/receiving limits automatically. Source

USGS Water Science School: Water density. Plain-water density context supports the conservative 16..16.5 g/in3 budget over 40..95 F. This is not evidence of an actual water trial. Source

W. W. Grainger: 856YN8 / 1-ppm-4c-275 #4-40 x 2.75 in pan-head screw. Published 2.75 in under-head length, 7/32 in maximum pan-head diameter, 5/64 in maximum height and minimum 1.5 in threaded tail. Actual receiving remains required. Source

PESOLA: 40300 Medio Line 300 g / 2 g spring balance. 300 g range, 2 g divisions, +/- .3% precision and no user calibration. The larger original per-reading/difference budgets include reading and zero allowances. Source

PENCOM: Type B narrow washer catalog, printed page 102. Nominal #4 Type B narrow washer dimensions are .032 in thick, .125 ID and .250 OD. Complete eccentric envelope limits in this construction are original receiving gates. Source

Albany County Fasteners: #4-40 low-profile nylon-insert 316 stainless hex nut. Nominal .251 in across flats and .125 in height. Actual corner envelope, height and complete thread projection must be received; no substituted tall nut is covered. Source

JC Fasteners: ASME B18.3-1 SS316 socket-head cap screw table. Primary SS316 socket-cap table: #4-40 head maximum .183 D/.112 H and named 1 in / 1.75 in length candidates. The length codes are marked nonpreferred/limited availability; no current stock is promised. Original received maximum .185 D/.115 H and minimum .5 in full tip thread apply as actual receiving gates, not a catalog thread-length promise. No rated property is transferred. Source